Twenty reference microgrids. Open any of them.
From an 8 kW arctic telecom relay to a 2 MW island feeder. Loads, weather and prices are synthetic and labelled as such: these are regression anchors and starting points, not measured projects and not validation against another engine.
- telecom · arctic8 kW peak
Arctic telecom relay
Extreme cold, highly stable 24/7 load, scarce winter sun.
- Starting design
- 50 kW PV · 20 kWh · 10 kW gen
- Renewable share
- 29%
- Unmet load
- 0%
- LCOE (real)
- $0.771/kWh
- NPC vs diesel-only
- 20% higher
- Resource
- Offline estimate
- telecom · desert12 kW peak
Desert telecom relay
High irradiance, battery thermal stress.
- Starting design
- 20 kW PV · 50 kWh · 15 kW gen
- Renewable share
- 45%
- Unmet load
- 0%
- LCOE (real)
- $0.516/kWh
- NPC vs diesel-only
- 7% lower
- Resource
- Offline estimate
- clinic · tropical20 kW peak
Remote clinic (small)
Refrigeration-critical vaccine cold chain.
- Starting design
- 50 kW PV · 50 kWh · 30 kW gen
- Renewable share
- 55%
- Unmet load
- 0%
- LCOE (real)
- $0.542/kWh
- NPC vs diesel-only
- 10% lower
- Resource
- Offline estimate
- clinic · desert60 kW peak
Remote clinic (medium)
Nighttime reliability emphasis.
- Starting design
- 100 kW PV · 200 kWh · 70 kW gen
- Renewable share
- 62%
- Unmet load
- 0%
- LCOE (real)
- $0.461/kWh
- NPC vs diesel-only
- 15% lower
- Resource
- Offline estimate
- hospitality · tropical80 kW peak
Island guesthouse
Solar-rich, diesel backup.
- Starting design
- 200 kW PV · 200 kWh · 100 kW gen
- Renewable share
- 47%
- Unmet load
- 0%
- LCOE (real)
- $0.454/kWh
- NPC vs diesel-only
- 28% lower
- Resource
- Offline estimate
- hospitality · tropical300 kW peak
Island resort
Strong daily cycling.
- Starting design
- 1.00 MW PV · 1,000 kWh · 400 kW gen
- Renewable share
- 47%
- Unmet load
- 0%
- LCOE (real)
- $0.501/kWh
- NPC vs diesel-only
- 5% lower
- Resource
- Offline estimate
- school · continental40 kW peak
Rural school
Weekday-dominant load.
- Starting design
- 50 kW PV · 100 kWh · 50 kW gen
- Renewable share
- 69%
- Unmet load
- 0%
- LCOE (real)
- $0.522/kWh
- NPC vs diesel-only
- 12% lower
- Resource
- Offline estimate
- school · temperate120 kW peak
Boarding school
Evening peaks, residential dorms.
- Starting design
- 200 kW PV · 500 kWh · 150 kW gen
- Renewable share
- 79%
- Unmet load
- 0%
- LCOE (real)
- $0.458/kWh
- NPC vs diesel-only
- 16% lower
- Resource
- Offline estimate
- village · desert50 kW peak
Village microgrid (tiny)
Load-growth sensitivity.
- Starting design
- 50 kW PV · 200 kWh · 70 kW gen
- Renewable share
- 49%
- Unmet load
- 0%
- LCOE (real)
- $0.644/kWh
- NPC vs diesel-only
- 2% higher
- Resource
- Offline estimate
- village · desert150 kW peak
Village microgrid (small)
Productive-load uncertainty.
- Starting design
- 200 kW PV · 500 kWh · 200 kW gen
- Renewable share
- 52%
- Unmet load
- 0%
- LCOE (real)
- $0.550/kWh
- NPC vs diesel-only
- 10% lower
- Resource
- Offline estimate
- village · tropical400 kW peak
Village microgrid (medium)
Generator sizing sensitivity (single aggregate genset modeled).
- Starting design
- 1.00 MW PV · 1,000 kWh · 500 kW gen
- Renewable share
- 42%
- Unmet load
- 0%
- LCOE (real)
- $0.553/kWh
- NPC vs diesel-only
- 6% higher
- Resource
- Offline estimate
- mine-camp · desert250 kW peak
Mine camp (small)
High diesel displacement value.
- Starting design
- 500 kW PV · 1,000 kWh · 300 kW gen
- Renewable share
- 54%
- Unmet load
- 0%
- LCOE (real)
- $0.411/kWh
- NPC vs diesel-only
- 16% lower
- Resource
- Offline estimate
- mine-camp · arctic1.00 MW peak
Mine camp (medium)
Strong redundancy requirement.
- Starting design
- 5.00 MW PV · 2,000 kWh · 1.50 MW gen
- Renewable share
- 39%
- Unmet load
- 0%
- LCOE (real)
- $0.550/kWh
- NPC vs diesel-only
- 2% higher
- Resource
- Offline estimate
- cold-storage · desert150 kW peak
Cold storage agro site
Strong refrigeration base load.
- Starting design
- 200 kW PV · 500 kWh · 200 kW gen
- Renewable share
- 44%
- Unmet load
- 0%
- LCOE (real)
- $0.441/kWh
- NPC vs diesel-only
- 16% lower
- Resource
- Offline estimate
- water-pumping · desert75 kW peak
Water pumping station
Dispatchable daytime pumping.
- Starting design
- 100 kW PV · 200 kWh · 100 kW gen
- Renewable share
- 72%
- Unmet load
- 0%
- LCOE (real)
- $0.475/kWh
- NPC vs diesel-only
- 23% lower
- Resource
- Offline estimate
- cold-storage · temperate200 kW peak
Fisheries / ice plant
High morning/evening peaks, ice making.
- Starting design
- 1.00 MW PV · 500 kWh · 300 kW gen
- Renewable share
- 47%
- Unmet load
- 0%
- LCOE (real)
- $0.588/kWh
- NPC vs diesel-only
- 2% higher
- Resource
- Offline estimate
- utility-feeder · temperate500 kW peak
Remote municipality
Mixed critical / non-critical loads.
- Starting design
- 2.00 MW PV · 1,000 kWh · 700 kW gen
- Renewable share
- 46%
- Unmet load
- 0%
- LCOE (real)
- $0.499/kWh
- NPC vs diesel-only
- 8% higher
- Resource
- Offline estimate
- mine-camp · desert300 kW peak
Construction camp
Short project horizon, temporary site.
- Starting design
- 1.00 MW PV · 1,000 kWh · 400 kW gen
- Renewable share
- 48%
- Unmet load
- 0%
- LCOE (real)
- $0.461/kWh
- NPC vs diesel-only
- 5% lower
- Resource
- Offline estimate
- military · desert750 kW peak
Remote military support base
Reliability and fuel resilience priority.
- Starting design
- 2.00 MW PV · 2,000 kWh · 1.00 MW gen
- Renewable share
- 48%
- Unmet load
- 0%
- LCOE (real)
- $0.453/kWh
- NPC vs diesel-only
- 15% lower
- Resource
- Offline estimate
- utility-feeder · tropical2.00 MW peak
High-fuel-cost island feeder
High fuel-scarcity cost (multi-generator staging is a roadmap item).
- Starting design
- 5.00 MW PV · 5,000 kWh · 3.00 MW gen
- Renewable share
- 50%
- Unmet load
- 0%
- LCOE (real)
- $0.454/kWh
- NPC vs diesel-only
- 22% lower
- Resource
- Offline estimate
Inputs and starting designs
The same cases as a table. Annual load and outputs are recomputed by the engine on every build; the JSON adds the resource provenance and an input fingerprint.
Illustrative delivered diesel price for a synthetic benchmark (MicrogridModeler assumption, not a market quote). For scale: U.S. on-highway retail was $6.529/gal ($1.72/L) in the week of 2026-09-21 (EIA). Copy reviewed 2026-09-25.